Rain-down application. It happens at night. As a member of a team, with an assignment, an attack line, protective gear, a foam proportioning device, a nozzle, foam concentrates and a water supply, you put out an ignitable liquid fire: you choose the right foam for the fuel and conditions, lay a properly proportioned foam blanket on the fuel and keep it there, put the fire out, prevent reignition, protect the team with the foam stream and face the hazard until you reach a safe haven. It is station 5-3 of Ohio's Firefighter II practical exam (NFPA 1001 5.3.1).

Free to start

This scenario

  • Rain-down application.
  • It happens at night.

The steps

  1. Choose the right foam concentrate for the fuel and conditions.
  2. Prepare the foam concentrate supply for use.
  3. Choose and assemble the foam stream components correctly.
  4. Apply a properly proportioned foam stream with one of the techniques in the scenarios, as the foam and fuel require.
  5. Create and keep the foam blanket.
  6. Put the fire out and prevent reignition.
  7. Approach and retreat from spills as part of a coordinated team.
  8. Face the hazard until you reach a safe haven.
  9. No unsafe act during the evaluation.

To pass

  • All 9 steps.
  • The backup line must be in place before the fuel is lit.
  • With Class B foam on a flammable or combustible liquid fire, the fire should be at least 100 square feet (9.3 m²); you do not have to calculate application rates, and training foam or gas-fired props can be used.
  • The evaluator can stop the station at any time for an unsafe act.

Official source

State · Ohio EMS 5920

Firefighter II Practical Examination Skill Sheets (EMS 5920)

Ohio publishes every Firefighter II skill sheet free: the steps, the critical points and the minimum to pass.

Making Synapses is not affiliated with, sponsored by or endorsed by NFPA, IFSAC, Pro Board, OSHA or any state agency. NFPA 1001 and NFPA 1010 are trademarks of their respective owners and are named only to describe the exams.